- Product Details
- Parameter
Overview
√ Multiple operating modes, on-grid, off-grid, and UPS, with built-in MPPT charge controllers
√ Built-in DSP control, using SPWM technique
√ Supports communication and can be remotely diagnosed and updated through
smart APP
√ Self-developed BMS with excellent battery capacity balancing ability
Technical Specifications |
Model |
CET-9335-H3 |
CET-9335-H5 |
Battery Data |
Battery Type |
Lithium/Lead-Acid |
Li-Ion/Lead-Acid |
Nominal Battery Voltage(V) |
51.2 |
51.2 |
Battery Voltage Range(V) |
41.6~58.5 |
41.6~58.5 |
Max. Continuous Charging Current(A) |
80 |
95 |
Max. Continuous Discharging Current(A) |
85 |
100 |
Max. Charging Power(W) |
3600 |
5000 |
Max.Discharging Power(W) |
3600 |
5000 |
PV String Input Data |
Max. Input Power(W) |
5200 |
7000 |
Max. Input Voltage(V) |
500 |
500 |
MPPT Operating Voltage Range(V) |
120~430 |
120~430 |
Start-up Voltage(V) |
150 |
150 |
Nominal Input Voltage(V) |
360 |
360 |
Max. Input Current per MPPT(A) |
15 |
15 |
Max. Short Circuit Current per MPPT(A) |
18.9 |
18.9 |
Number of MPP Trackers |
2 |
2 |
Number of Strings per MPPT |
1 |
1 |
AC Output Data (On-grid) |
Rated Power Output to Utility Grid(W) |
3600 |
5000 |
Max. Apparent Power Output to Utility Grid (VA) |
3960 |
5500 |
Max. Apparent Power from Utility Grid (VA) |
3960 |
5500 |
Nominal Output Voltage(V) |
220/230/240 |
220/230/240 |
NominalACGridFrequency (Hz) |
50/60 |
50/60 |
Max. AC Current Output to Utility Grid(A) |
17.2 |
23.9 |
Max. AC Current Output from Utility Grid(A) |
17.2 |
23.9 |
Max. Total Harmonic Distortion |
<3% |
<3% |
Power Factor (Cos φ) |
0.99 |
|
Switch Time |
<10ms |
<10ms |
AC Output Data (Backup) |
Back-up Rated Power (W) |
3600 |
4500 |
Max. Output Apparent Power (VA) |
3600 |
4500 |
Max. Output Current(A) |
15.6 |
20 |
Nominal Output Voltage(V) |
220/230/240 |
220/230/240 |
NominalOutputFrequency(Hz) |
50/60 |
50/60 |
Output THDv (@Linear Load) |
<3% |
<3% |